If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Magnetic Overcurrent Circuit Breaker 808-... Description Single pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically separate excitation and switching circuits, and one pair of auxiliary contacts which close when the main circuit is open. Also suitable for impulse operation. Designed for printed circuit board mounting. Low temperature sensitivity. NEW Typical applications Printed circuit boards and components, safety and control systems. 808 Ordering information Type No. 808 fast-acting Manual release (optional) H manual release facility Current ratings 0.01 ...8 A 808 H - 1A ordering example Technical data Voltage rating Current ratings Max. continuous load excitation circuit (2-3) Max. continuous load switching circuit 6-7 auxiliary circuit 4-5 Typical life Ambient temperature Insulation co-ordination (IEC 60664 and 60664A) DC 24 V UL, CSA: AC 120 V, DC 60 V 0.01...8 A 2.65 x IN 3 Packaging quantity: 250 pcs 5A 6,000 operations at 5 A for switching circuit -30...+70 C (-22...+158 F) Rated impulse withstand voltage 1.5 kV Test voltage AC 840 V Pollution degree 2 Standard current ratings and typical internal resistance values Current rating (A) 0.01 0.02 0.03 0.04 0.05 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Internal resistance () 625 170 77 47 29.2 10.3 5.6 1.65 0.89 0.39 0.28 0.198 0.143 Current rating (A) 0.8 0.9 1 1.2 1.5 2 2.5 3 3.25 4 4,5 5 8 Internal resistance () 0.096 0.085 0.073 0.050 0.031 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 Dielectric strength (IEC 60664 and 60664A) excitation to switching circuit excitation to auxiliary circuit Insulation resistance Interrupting capacity (o-o-o) Interrupting capacity (UL 1077) Degree of protection (IEC 60529/DIN 40050) Vibration AC 1,680 V > 100 M (DC 500 V) 100 A 1,000 A AC 120 V 200 A DC 60 V operating area IP 30 terminal area IP 00 3 g (57-500 Hz), 0.23 mm (10-57 Hz), to IEC 60068-2-6, test Fc 10 frequency cycles/axis 25 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 10 g Shock Corrosion Humidity Mass Approvals Authority CSA UL Voltage ratings AC 120 V, DC 60 V DC 60 V AC 120 V Current ratings 0.01 ...5 A 0.01 ...8 A 0.01 ...5 A Issue C USA (847) 827-7600 - CANADA (905) 764-9510 171 Magnetic Overcurrent Circuit Breaker 808-... Dimensions 808 20 .787 o9.3 .366 Internal connection diagram 5 OFF .197 4 5 7 2-3: excitation circuit 6-7: switching circuit 4-5: auxiliary circuit 0 ON o4 .157 5 .197 6 2 + 3 30 1.18 5 .197 14 .551 Typical time/current characteristics at +23C/+73.4F 0.5 .020 10 .394 15.5 .610 Trip time in milliseconds 10000 15 .591 3 808-H 20 .787 o9.3 .366 0.6 .024 1000 100 10 2.5 ON .098 7.5 OFF .295 o4 .157 5 .197 1 5 .197 0.1 1 2 4 6 8 10 20 40 ... times rated current 30 1.18 14 .551 15 .591 0.6 .024 0.5 .020 10 .394 15.5 .610 This is a metric design and millimeter dimensions take precedence ( inch ) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. mm 172 USA (847) 827-7600 - CANADA (905) 764-9510 Issue C |
Price & Availability of 808-H-2A |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |